We appreciate your visit to A single acting reciprocating compressor operates at 150 rpm with initial air conditions of 97 9 kPaa and 27 C discharging air at 379 kPaa. This page offers clear insights and highlights the essential aspects of the topic. Our goal is to provide a helpful and engaging learning experience. Explore the content and find the answers you need!
Answer :
To solve this problem, we have to follow several steps for both parts: determining the Free Air Capacity (CFM) and the power in kW.
Given Data:
- Initial pressure, [tex]P_1 = 97.9 \, \text{kPa}[/tex]
- Initial temperature, [tex]T_1 = 27^\circ C = 300.15 \, \text{K}[/tex]
- Discharge pressure, [tex]P_2 = 379 \, \text{kPa}[/tex]
- Atmospheric pressure, [tex]P_{atm} = 100 \, \text{kPa}[/tex]
- Atmospheric temperature, [tex]T_{atm} = 20^\circ C = 293.15 \, \text{K}[/tex]
- Bore, [tex]D = 355 \, \text{mm} = 0.355 \, \text{m}[/tex]
- Stroke, [tex]L = 381 \, \text{mm} = 0.381 \, \text{m}[/tex]
- Clearance volume percentage, [tex]C = 5\% = 0.05[/tex]
- Speed, [tex]N = 150 \, \text{rpm}[/tex]
- Compression and expansion process: [tex]pv^{1.3} = C[/tex]
(a) Free Air Capacity (CFM)
First, compute the swept volume ([tex]V_s[/tex]) and clearance volume ([tex]V_c[/tex]):
[tex]V_s = \frac{\pi}{4} D^2 L[/tex]
[tex]V_c = C \times V_s[/tex]
Next, determine the volume at the start of compression ([tex]V_1[/tex]) and discharge ([tex]V_2[/tex]):
[tex]V_1 = V_s + V_c[/tex]
[tex]\frac{V_1}{V_2} = \left(\frac{P_2}{P_1}\right)^{1/n} \text{, where } n = 1.3[/tex]
Calculate [tex]V_2[/tex], when rearranged:
[tex]V_2 = \frac{V_1}{\left(\frac{P_2}{P_1}\right)^{1/n}}[/tex]
The swept volume during discharge (9) is [tex]V_s - V_2[/tex], and converting to cubic feet per minute (CFM):
[tex]\text{Free Air Delivery (FAD)} = \text{Volumetric Efficiency} \times N \times V_s \times \frac{1}{35.315} \text{ (Convert \(m^3/min\) to CFM)}[/tex]
Volumetric efficiency is calculated considering clearance volumes.
(b) Power in kW
The indicated power for compression is given by:
[tex]\text{Indicated Power } = \frac{N}{60} \times \text{Number of Cylinders} \times \left( \frac{P_1V_1^n - P_2V_2^n}{n-1} \right)[/tex]
Then convert from [tex]\text{J}[/tex] to [tex]\text{kW}[/tex]:
Finally, compute real power considering mechanical efficiency.
Note, each of these steps involves substituting known quantities and solving the mathematical expressions. The final result provides FAD in CFM and required power in kW.
It's important to ensure unit consistency and proper conversion, especially from cubic meters to cubic feet and from pressure/volume units. Complex equations and intermediate results should be thoroughly checked for accuracy.
Thanks for taking the time to read A single acting reciprocating compressor operates at 150 rpm with initial air conditions of 97 9 kPaa and 27 C discharging air at 379 kPaa. We hope the insights shared have been valuable and enhanced your understanding of the topic. Don�t hesitate to browse our website for more informative and engaging content!
- Why do Businesses Exist Why does Starbucks Exist What Service does Starbucks Provide Really what is their product.
- The pattern of numbers below is an arithmetic sequence tex 14 24 34 44 54 ldots tex Which statement describes the recursive function used to..
- Morgan felt the need to streamline Edison Electric What changes did Morgan make.
Rewritten by : Barada