Answer :
Final answer:
Calibration of a blood gas analyzer involves cleaning the device, using calibration gases with known concentrations, allowing the analyzer to adjust its settings based on values of these gases, running a control sample to validate the calibration, and repeating the process if the result isn't within the expected range.
Explanation:
Performing calibration on a blood gas analyzer is a critically important procedure to ensure accurate results when assessing a patient's blood gas levels. It involves several steps:
- Firstly, ensure that the analyzer is cleaned thoroughly to avoid any contamination that could affect the results.
- Secondly, it's necessary to perform a two-point calibration using calibration gases that have known concentrations, typically one at a high level and the other at a low level. These known values will serve as reference points for your analyzer.
- Next, introduce these gases into the analyzer one at a time and allow the analyzer to read and adjust its settings based on these readings.
- After the calibration procedure, it's recommended to run a control sample with a known blood gas concentration to verify the accuracy of the calibration.
- If the control sample result is within the expected range, then the calibration was successful. If not, the process should be repeated.
The frequency of the calibration may vary depending on the manufacturer's instructions or lab policy but it is usually done periodically before testing each set of patient samples.
Learn more about calibration here:
https://brainly.com/question/34842833
#SPJ11
Thanks for taking the time to read how do you perform calibration on a blood gas analyzer. We hope the insights shared have been valuable and enhanced your understanding of the topic. Don�t hesitate to browse our website for more informative and engaging content!
- Why do Businesses Exist Why does Starbucks Exist What Service does Starbucks Provide Really what is their product.
- The pattern of numbers below is an arithmetic sequence tex 14 24 34 44 54 ldots tex Which statement describes the recursive function used to..
- Morgan felt the need to streamline Edison Electric What changes did Morgan make.
Rewritten by : Barada